Vue de la page 0
3
Operating instructions
3B SCIENTIFIC® PHYSICS
U40110 Multiple Beam Lamp
1/03 ALF
1 Rotary mirror for focused, parallel light beams
2 Rotary mirror for divergent light beams
3 Protective cover
4 Electrical power cable with a 4-mm plug
5 Central ray
®
The multiple beam lamp allows numerous demonstra-
tions in the areas of ray and wave optics when used
with the equipment set for optics on magnetic boards,
basic set (U14600) and supplementary set (U14601). The
demonstrations include casting of shadows, chromat-
ics, reflection laws, refraction laws, total reflection,
minimum angle of deflection in a prism, ascertaining
the focal length of mirrors and lenses, lens laws and
aberrations.
1. Safety instructions
Caution: Lamps heat up during extended periods
of operation.
Do not touch the glass bulb of the lamp with your
bare hands when changing the bulb, for example.
Lamp bulbs are clouded by fat deposits on the
skin.
2. Description, technical data
The device comprises a halogen lamp in a metal hous-
ing lined with magnetic foil. The light source emits up
to 5 narrow beams which are deflected by rotary mir-
rors so as to emerge parallel, convergent or divergent.
Up to 2 divergent light beams whose area of overlap
can be adjusted by means of mirrors are available on
the rear of the multi-beam lamp.
Lamp: 12V, 55W
Power cable: 1.5 m long with a 4-mm plug
Dimensions: 150 mm x 200 mm x 50 mm
Weight: 0.9 kg
2.1 Accessories:
U40113 Spare halogen light for the multiple beam lamp
U40110.
3. Procedure
3.1 Setting a parallel light beam
Attach the lamp to the board.
Plug the lamp into a power supply unit, for in-
stance, U11735.
Adjust the beam via rotary mirror 1.
3.2 Setting a divergent light beam
Attach the lamp to the board.
Plug the lamp into a power supply unit, for in-
stance, U11735.
Adjust the beam via rotary mirror 2.
3.3 Changing bulbs
Loosen the screws, remove the round protective
cover (A) and the spacers.
Remove the flat plug (E), loosen the knurled screws
(B), remove the plate (C) and the lamp (D).
Insert a new lamp. Fasten the plate again with
knurled screws such that the lamp can still be
moved.
Do not touch the glass bulb of the lamp with your
bare hands when changing it. Lamp bulbs are
2
1
1
1
3
2
4
1
5
Vue de la page 0
1 2

Résumé du contenu

Page 1 - U40110 Multiple Beam Lamp

3Operating instructions3B SCIENTIFIC® PHYSICSU40110 Multiple Beam Lamp1/03 ALF1 Rotary mirror for focused, parallel light beams2 Rotary mirror for div

Page 2

43B Scientific GmbH • Rudorffweg 8 • 21031 Hamburg • Germany • www.3bscientific.com • Technical amendments are possibleclouded by fat deposits on the

Modèles reliés U40110

Commentaires sur ces manuels

Pas de commentaire